Description
Pioneer 12,000 BTU 21.5 SEER 115V Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System with 16 ft. Line Sets – WYS012AMFI22RL-16
At Pioneer Mini Split, we offer variable capacity ductless wall-mounted mini split systems, available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Our ductless mini split wall-mounted air conditioners and heat pumps come with a convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall-mount ductless mini split system, while automatic air-sweeping louvers, automatically varying air flow, and capacity adjustments keep the zone at the ultimate comfort level. This results in minimal electrical consumption for a more efficient ductless wall air conditioner and heating system. Check out our selection of wall-mounted heating and cooling units today!
Features
- Ultra High Efficiency Inverter++ ductless mini split heat pump system
- Cooling capacity: 12,000 BTU/H with 21.5 SEER/12.5 EER efficiency
- Heating capacity: 12,000 BTU/H with 11.5 HSPF/3.38 COP efficiency
- Voltage: 110~120 V, 60 Hertz, 1Ph
- High Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Customizable length copper line set with flare connections
- Energy-Star Certified
- AHRI Estimated Annual Operating Costs:
- Cooling: $74.00
- Heating: $221.00
-
Sleep Mode
The function enables the air conditioner to automatically increase cooling or decrease heating 1°C per hour for the first two hours, then holds steady for the next 5 hours, after that it will switch off. This function maintains both energy savings and comfort at night. -
Temperature Compensation
Temperature compensation function eliminates the difference in temperature between the floor and ceiling by mixing the different layers of air. Consequently, the time for cooling the room is reduced, and a cold offset rising stream of warm air by stirring. -
Refrigerant Leakage Detect
Indoor unit shows error code “EC” and stops automatically when refrigerant leakage is detected. This protects the compressor from high temperature damage due to refrigerant leakage. -
Anti-cold Air Function
Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to evaporator temperature when the unit just starts heating operation. This function can prevent cold air blowing out to avoid discomfort to the users. - Emergency start
-
Low Ambient Cooling
With built-in low ambient kit or special designed PCB, outdoor fan speeds can be changed automatically according to condensation temperature. The air conditioner can run heating operation even when the outdoor ambient temperature is down to -13°F. -
1W Standby
Intelligent on-off technology enables Pioneer products automatically enter energy-saving mode when standby, cut energy consumption from normal 5W to 1W or 0.5W per hour which counts 80%~90% of saving. -
2-way Draining
Both left and right sides of the indoor unit are possible for outstretch of connective piping and drainage hose for easy installation. -
Follow Me (Remote Thermostat)
Temperature sensor built in the remote controller will sense it’s surrounding temperature. The unit will adjust the room temperature more accurately to give you comfort. -
46°F Heating
In heating operation, the preset temperature of the air conditioner can be as low as 46°F, which keeps the room temperature steady at 46°F and prevents the house from freezing when it is unoccupied for a long time in severe cold weather. -
Chassis Heating Belt
Heating belt is fitted on the base plate of the outdoor unit to prevent defrosting water accumulation, which improves heat transfer efficiency.
Optional
- High Density Filter. Compared with ordinary dust filter, the anti-dust effect of this high density filter can increase more than 50%, it can clean dust, pollen up to 80%.
- Wireless Control. With the Wireless control, you can easily turn off each indoor unit that it is paired, outside your home via your smart phone. Furthermore, you can turn it on before you come back.
- Remote in Engineer Mode
What’s Included
- Indoor Unit
- Outdoor Unit
- Wireless Remote Control
- R410A Pre-Charged Outdoor Unit
- Various Installation Kit Options Available
- Flare Connection Leak Guard Sealer
- Installation Manual
- User’s Manual
- Manufacturer Warranty
Specifications
Performance Data | |
---|---|
Power Supply | 110~120V, 60Hz, 1Ph |
Cooling Rated Capacity | 12,000 BTU/h |
Cooling Capacity Range | 3,500~12,150 BTU/h |
Cooling SEER | 21.5 BTU/w |
Cooling EER | 12.5 BTU/w |
SEER2 | 22.7 |
Heating Rated Capacity | 12,000 BTU/h |
Heating Capacity Range | 4,600~12,904 BTU/h |
Heating HSPF | 11.5 BTU/w |
Refrigerant Type | R410a |
Suitable Area | 300~450 Sq.F |
Warranty | 5 years parts and compressor warranty |
Condenser | |
Sound Level | 52.5 dB(A) |
Breaker Needed | 20A (single-pole) |
Net Dimensions (WDH) | 30.2″W x 11.8″ D x 21.7″ H |
Carton Dimensions (WDH) | 34.8″ W x 13.25″ D x 24″ H |
Net / Gross Weight | 66.8 / 72.3 Lbs |
Cool Mode – Outdoor Operating Temperature Range | 5° to 122°F |
Heat Mode – Outdoor Operating Temperature Range | -13° to 75°F |
Air Handler | |
Air Flow (Hi/Med/Lo) | 306 / 212 / 147 CFM |
Sound Level (Hi/Lo) | 36.0 / 23.0 dB(A) |
Net Dimensions (WDH) | 31.5″ W x 7.3″ D x 11.6″ H |
Carton Dimensions (WDH) | 34.5″ W x 11.25″ D x 15″ H |
Net / Gross Weight | 24 / 34.2 Lbs |
INSTALLATION & GUIDES
What Our Experts Think
- High-Capacity Performance: 24,000 BTU with a 21 SEER rating delivers exceptional cooling and heating for larger spaces, ensuring powerful temperature control without excessive energy consumption.
- Inverter++ Technology: Optimizes performance by adjusting the compressor speed to maintain the desired temperature, enhancing energy efficiency and providing quieter operation.
- Ideal for Larger Spaces: Perfect for larger rooms, open floor plans, or multi-room setups, offering effective climate control without the need for traditional ductwork.
- Quiet & Efficient: Equipped with noise-reduction technology, ensuring a quiet and comfortable environment while maximizing efficiency.
- Year-Round Comfort: Provides efficient cooling in the summer and heating in the winter, making it a versatile choice for year-round use.
Q&A
Q: What is the Pioneer 24,000 BTU 21 SEER Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System?
A: This high-capacity mini-split system provides both cooling and heating with a 21 SEER rating. Equipped with Inverter++ technology, it ensures energy-efficient, quiet operation and precise temperature control. This version does not include an installation kit, offering flexibility in setup.
Q: How does Inverter++ technology enhance system performance?
A: Inverter++ technology adjusts the compressor speed to match temperature demand, improving energy efficiency, reducing noise, and maintaining a comfortable, consistent environment.
Q: What room size is this system suitable for?
A: This system is ideal for cooling and heating larger spaces, covering up to 1,000 sq. ft.
Q: Is it suitable for residential use?
A: Yes, it’s perfect for larger residential applications, providing effective climate control with minimal noise and energy consumption.
Q: Does it require professional installation?
A: Since this unit does not come with an installation kit, professional installation is recommended for optimal performance and reliability.
Maintenance Tips
-
Clean the Air Filters Regularly: Clean the air filters every 1-2 months to maintain proper airflow and efficiency. Gently vacuum or rinse them with water to remove accumulated dust and dirt. Allow the filters to dry completely before reinserting them into the unit.
-
Inspect and Clean the Coils: Dirty evaporator and condenser coils can reduce system efficiency and performance. Every 6 months, inspect the coils and gently clean them with a soft brush or compressed air to remove dirt and debris.
-
Check for Ice or Frost Buildup: If you notice ice or frost forming on the evaporator coils, it could indicate restricted airflow or a refrigerant issue. Turn off the unit and let it thaw before checking for potential airflow blockages or scheduling a professional inspection.
-
Ensure Proper Drainage: The condensate drain should be clear to prevent water damage and maintain proper cooling and heating. Regularly inspect and clean the drainage system, using a wet/dry vacuum if necessary to clear clogs and ensure efficient drainage.
-
Monitor Refrigerant Levels: If the system is not cooling or heating properly, low refrigerant levels could be the cause. Have a certified technician check the refrigerant level annually, and repair any leaks if necessary to prevent further issues.
-
Check the Outdoor Unit: Ensure that the outdoor condenser unit is free of debris, such as leaves, dirt, or branches, that can obstruct airflow. A clean outdoor unit will run more efficiently and prevent overheating.
-
Inspect the Refrigerant Lines: Examine the refrigerant lines for any signs of wear or damage, including insulation issues. Properly insulated lines help prevent energy loss, so replace damaged insulation to maintain system efficiency.
-
Watch for Unusual Noises or Behavior: Pay attention to any strange sounds (e.g., grinding, buzzing, or rattling) or performance issues, such as poor cooling or heating. Unusual noises or irregular behavior may signal a mechanical issue that needs professional attention.
-
Schedule Annual Professional Maintenance: To keep your Pioneer 24,000 BTU Ductless Mini-Split in optimal condition, schedule professional maintenance once a year. A technician can inspect all components, check refrigerant levels, clean the system, and make sure everything is working as it should.
Reviews