The Masimo Rad-57 is the world’s most versatile handheld oximeter with a rugged, lightweight design ideal for both field and hospital settings. This innovative device requires no user calibration and operates effectively without patient cooperation or consciousness, making it an excellent replacement for existing handheld pulse oximeters. The Rad-57 offers factory-ordered options or field-installed software upgrades for continuous monitoring and spot-check measurements of SpHb, SpOC, SpMet, and PVI.
Comprehensive Monitoring: Measures SpO2, SpCO, SpMet, Pulse Rate, and Perfusion Index.
Versatile Applications: Suitable for use in field or hospital settings.
No Calibration Needed: Eliminates the need for user calibration or patient cooperation.
Rugged Design: Lightweight yet durable for tough environments.
High Accuracy: Provides reliable SpO2 and pulse rate measurements during motion and low perfusion.
Perfusion Index: Indicates arterial pulse signal strength, aiding in diagnosis during low perfusion.
Extensive Battery Life: Over 8 hours of continuous monitoring.
SmartTone™ Technology: Beeps in sync with pulse, even under motion conditions.
FastSat Technology: Tracks rapid changes in arterial O2 with unmatched fidelity.
Trending Memory: Up to 72 hours of trending memory for key measurements.
Sensitivity Options: APOD, Normal, and MAX settings for a range of clinical applications.
Visual and Audible Alarms: Alerts for high/low saturation, pulse rate, and system issues.
Trending: | 72 hours of trending at 2-second resolution; output to PC running Masimo TrendCom™ Utility. |
---|---|
SpO2 Modes: | Averaging (2, 4, 8, 10, 12, 14, or 16 seconds), sensitivity (APOD, Normal, Max), FastSat (on/off) |
Alarms: |
Audible and visual for high/low saturation, pulse rate, sensor condition, system failure, low battery. |
Display/Indicators: | LED data display for %SpO2, %SpCO, %SpMet, pulse rate, perfusion index, and more. |
Compliance: | EMC EN60601-1-2, Class B; IEC 60601-1-1; Type BF-Applied part. |
Carboxyhemoglobin Saturation Accuracy: | SpCO: 1%-40%, ±3 digits. |
Methemoglobin Saturation Accuracy: | SpMet: 1%-15%, ±1 digit. |
The DRE Masimo Radical 57 Pulse Oximeter (DR-9842) is a top-tier solution for accurate and continuous monitoring of oxygen saturation and pulse rate in veterinary and medical settings. Known for its advanced technology, it ensures reliability in critical care scenarios:
Q: What technology does this oximeter use?
A: It features Masimo SET® technology, known for high accuracy and performance in low perfusion or motion conditions.
Q: Is it suitable for all animal sizes?
A: Yes, it is versatile and accommodates a range of patient sizes and species.
Q: Can it be used in mobile practices?
A: Absolutely, its compact and portable design makes it ideal for on-the-go use.
Q: What measurements does it provide?
A: It measures oxygen saturation (SpO₂), pulse rate, and perfusion index.
Q: Is it battery-operated?
A: Yes, the device operates on rechargeable batteries for convenience.